Contact dial thermometers are universally-applicable devices with actual value display for temperature measurement, control, and monitoring. The slow-action contact/magnetic snap contact closes or opens an electrical circuit depending on the movement direction at the set limit values.
general technical data | |
---|---|
Measuring range | -40 to +450 °C |
Display range | -50 to +500 °C |
Housing size | 100 mm, 160 mm, and front panel 96 × 96 mm |
Accuracy class according to DIN EN 13190 | Class 1 |
Features | Temperature controller in flush-mounted housing or surface-mounted housing; ambient temperature compensation |
Areas of application | Process technology, oven engineering |
Capillary/rigid thermowell | Rigid thermowell or capillary (up to 10 m) |
Probe outlet | Vertical or horizontal |