The transmitter can be used in liquids with a conductivity as of 20 μS/cm. Standardized fittings ensure simple insertion of the transmitter into pipes from DN 15 to DN 400. The output signal is 4 to 20 mA and the pulse frequency signal is 0 to 240 Hz.
general technical data | |
---|---|
Measuring range | 0.2 to 10 m/s |
Nominal pressure | PN 16 |
Medium temperature | Max. 150 °C |
Nominal pipe width | DN 15 to DN 400 |
Outputs | 4 to 20 mA; pulse frequency; switching output (changeover contact relay) |
Measuring accuracy | ≤ ± 3.5 % of the measured value (standard calibration factor); ≤ ± 0.5 % of the measured value (Teach-In) |
Parts in contact with medium | Stainless steel 316L (1.4404); FKM or EPDM; PEEK |
Protection type | IP65 |
Medium | Conductive liquids as of 20 μS/cm |
Voltage supply | DC 18 to 36 V |
Accessories | T-fittings made of PVC or stainless steel; PE or stainless steel welded socket; PP connection clamps (type 406090) |